detalle del documento
IDENTIFICACIÓN

doi:10.1186/s43055-023-01157-z...

Autor
Bawazeer, Omemh Fallatah, Alaa Alasmary, Mohamed Bokhary, Younis Almerabi, Areej Khan, Suha Abuhadi, Nouf Alalawi, Amani Asiri, Naseem Bawazir, Saeed Al-Qahtani, Saeed Algethami, Merfat Badawy, Mohamed
Langue
en
Editor

Springer

Categoría

Medicine & Public Health

Año

2023

fecha de cotización

29/11/2023

Palabras clave
radiation shield barium sulphate panoramic radiography radiation safety shielding eye radiography reduction shield radiation dose thyroid
Métrico

Resumen

Background Radiation shielding in radiology has historically been achieved with lead; however, there has been an increasing demand for radiation shielding to be more environmentally friendly.

Barium has shown promise as a substitute in many radiology applications.

This study aims to investigate a barium sulphate shield in protecting the thyroid and the eye lens during panoramic radiography.

Methods During a simulated panoramic examination, an anthropomorphic phantom and a solid-state detector measured the radiation dose to the surface thyroid and the eye lens.

The measurements were taken using no shield and a barium sulphate shield.

A Welch's T-test was employed to compute the shield's effect on radiation.

Two radiologists assessed the image quality with and without the thyroid shields.

Results The dose reduction was between 66 and 75% for the barium shield at the thyroid.

The dose reduction ranged between 15 and 61% in the eye region.

Images using a barium shield were deemed adequate for diagnostic interpretation.

Conclusions Barium shields effectively reduce the radiation dose in the thyroid region during panoramic radiography without degrading image quality.

The dose reduction depends on the tube voltage and the area of interest.

Bawazeer, Omemh,Fallatah, Alaa,Alasmary, Mohamed,Bokhary, Younis,Almerabi, Areej,Khan, Suha,Abuhadi, Nouf,Alalawi, Amani,Asiri, Naseem,Bawazir, Saeed,Al-Qahtani, Saeed,Algethami, Merfat,Badawy, Mohamed, 2023, Investigation of barium sulphate shielding during panoramic radiography, Springer

Documento

Abrir

Compartir

Fuente

Artículos recomendados por ES/IODE IA

High-Frequency Repetitive Magnetic Stimulation at the Sacrum Alleviates Chronic Constipation in Parkinson’s Patients
magnetic stimulation parkinson’s significant patients scale sacrum pd hf-rms chronic constipation scores
The mechanism of PFK-1 in the occurrence and development of bladder cancer by regulating ZEB1 lactylation
bladder cancer pfk-1 zeb1 lactylation glycolysis inhibits lactate glucose bc pfk-1 cancer lactylation cells bladder