Intracranial pressure (ICP) is an important parameter in clinical management and diagnosis of several neurological diseases which is indirectly measured via lumbar puncture (LP).

In routine measurements of cerebrospinal fluid pressure (P(CSF)) from lumbar region, a spinal needle and a spinal manometer are used.

P(CSF) measurement via LP with the use of a spinal manometer may not yield correct P(CSF) results due to prolonged times required to obtain an accurate pressure value.

Equilibrium pressure may be underestimated in circumstances where spinal manometry procedure is terminated prematurely, with the wrong assumption that equilibrium pressure is reached.

Elevated P(CSF) levels can lead to visual loss and brain damage when go undiagnosed.

In this study, the spinal needle-spinal manometer combination was modelled with a first-order differential equation and a time constant (τ) was defined as the product of the resistance to flow of the needle with the bore area of the manometer divided by the dynamic viscosity of CSF, i.e. τ= RA/ρ(CSF).

Each needle/manometer combination had a unique constant as a predictor of the equilibrium pressure.

The fluid pressure in the manometer rose in an exponential manner which was tested in a simulated environment using 22G spinal needles namely Braun-Spinocan, Pajunk-Sprotte and M.Schilling.

Curve fitting of the manometer readings were obtained with regression coefficients of R(2) ≥ 0.99 to determine measurement time constants.

The residual differences between predicted and true values were less than 1.18 cmH(2)O.

For a given needle/manometer combination, time required to reach equilibrium pressure was identical for all pressure levels.

P(CSF) measured at reduced times can easily be interpolated to their equilibrium level allowing clinicians to obtain P(CSF) values with high accuracy within seconds.

This method can be used as an indirect estimation of ICP in routine clinical practice.

SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12868-023-00805-4.

Yücel, Duygu,Ülgen, Yekta, 2023, A novel approach to CSF pressure measurement via lumbar puncture that shortens the measurement time with a high level of accuracy, BioMed Central

Document

Open Open

Share

Source

Articles recommended by ES/IODE AI

A Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière Disease
ménière disease p < detection imaging sequences 3d-zoomit 3d endolymphatic real tse reconstruction ir inversion-recovery hydrops ratio
Successful omental flap coverage repair of a rectovaginal fistula after low anterior resection: a case report
rectovaginal fistula rectal cancer low anterior resection omental flap muscle flap rectal cancer pod initial repair rvf flap omental lar coverage