Document detail
ID

oai:arXiv.org:2406.06873

Topic
Astrophysics - Instrumentation and...
Author
Hernandez, Svea Igoshev, Andrei Taylor, Jo Sahnow, David Jones, Logan
Category

sciences: astrophysics

Year

2024

listing date

6/19/2024

Keywords
observations optimized dark detector
Metrics

Abstract

Observations utilizing the ultraviolet capabilities of the Cosmic Origin Spectrograph (COS) onboard the Hubble Space Telescope are of unique value to the astronomy community.

Spectroscopy down to 900 A with COS has enabled new science areas.

However, contrary to the situation at longer wavelengths, these observations are limited by detector background noise.

The background correction currently applied by the standard calibration pipeline (CalCOS) is not optimized for faint targets, limiting the scientific value of low signal-to-noise observations.

In this work we investigate a possible dependence of the variations of the dark rate in both segments of the COS far-ultraviolet (FUV) detector on time, detector high voltage (HV), and solar activity.

Through our analysis we identified a number of detector states (on a configuration basis, e.g., HV and segment) characterizing the spatial distribution of dark counts, and created superdarks to be used in an optimized 2-dimensional (2D) background correction.

We have developed and tested Another COS Dark Correction (ACDC), a dedicated pipeline to perform a 2D background correction based on statistical methods, producing background-corrected and flux-calibrated spectra.

While our testing of ACDC showed an average improvement in S/N values of ~10%, in a few cases the improvements in S/N reached 60% across the whole wavelength range of individual segments.

;Comment: 12 pages, 6 figures, 3 tables, Accepted for publication in the Publications of the Astronomical Society of the Pacific

Hernandez, Svea,Igoshev, Andrei,Taylor, Jo,Sahnow, David,Jones, Logan, 2024, Pushing the limits of the Cosmic Origin Spectrograph (COS) with an optimized background correction

Document

Open

Share

Source

Articles recommended by ES/IODE AI

A Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière Disease
ménière disease p < detection imaging sequences 3d-zoomit 3d endolymphatic real tse reconstruction ir inversion-recovery hydrops ratio
Successful omental flap coverage repair of a rectovaginal fistula after low anterior resection: a case report
rectovaginal fistula rectal cancer low anterior resection omental flap muscle flap rectal cancer pod initial repair rvf flap omental lar coverage