Document detail
ID

oai:pubmedcentral.nih.gov:1055...

Topic
Full Length Article
Author
Yi, Fang Fang, Zhangfu Liang, Hanwen Huang, Lianrong Jiang, Mei Feng, Zien Xiang, Keheng Chen, Zhe Luo, Wei Lai, Kefang
Langue
en
Editor

World Allergy Organization

Category

The World Allergy Organization Journal

Year

2023

listing date

8/16/2024

Keywords
identifying auc tige diagnostic eosinophils cough chronic [0 0 patients feno sputum blood
Metrics

Abstract

BACKGROUND: Sputum eosinophilia is a treatable trait for chronic cough.

It is currently not clear whether the blood eosinophil counts could be used to identify sputum eosinophilia in patients with chronic cough.

This study aimed to evaluate the diagnostic accuracy of blood eosinophils in comparison to other common type 2 biomarkers for identifying sputum eosinophilia in patients with chronic cough.

METHODS: In this prospective study, a total of 658 patients with chronic cough were enrolled.

Induced-sputum test, routine blood test, total immunoglobulin E (TIgE), and fractional exhaled nitric oxide (FeNO) level were measured.

The percentage of sputum eosinophils (Eos%) ≥ 2.5% was defined as sputum eosinophilia.

The area under the curve (AUC) of blood eosinophil counts, TIgE, and FeNO alone or in combination for predicting sputum eosinophilia were analyzed.

RESULTS: The AUC of blood eosinophil counts for predicting sputum eosinophilia in chronic cough patients was moderate [0.826 (0.767–0.885)], as compared to that of FeNO [0.784 (0.720–0.849), P = 0.280] and TIgE [0.686 (0.613–0.760), P = 0.001].

When combining blood eosinophil counts and FeNO for detecting sputum eosinophilia, a significantly larger AUC [0.868 (0.814–0.923), with a sensitivity of 84.2% and a specificity of 82.8%] was yielded, as compared to each single marker alone (all P < 0.05).

CONCLUSIONS: Blood eosinophil counts have a moderate diagnostic value for identifying sputum eosinophilia in patients with chronic cough, while a combination of blood eosinophil counts and FeNO measurement can provide additional predictive value.

Yi, Fang,Fang, Zhangfu,Liang, Hanwen,Huang, Lianrong,Jiang, Mei,Feng, Zien,Xiang, Keheng,Chen, Zhe,Luo, Wei,Lai, Kefang, 2023, Diagnostic accuracy of blood eosinophils in comparison to other common biomarkers for identifying sputum eosinophilia in patients with chronic cough, World Allergy Organization

Document

Open Open

Share

Source

Articles recommended by ES/IODE AI

A Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière Disease
ménière disease p < detection imaging sequences 3d-zoomit 3d endolymphatic real tse reconstruction ir inversion-recovery hydrops ratio
Successful omental flap coverage repair of a rectovaginal fistula after low anterior resection: a case report
rectovaginal fistula rectal cancer low anterior resection omental flap muscle flap rectal cancer pod initial repair rvf flap omental lar coverage