The intensity spectra recovered from the spectroscopic photographic plates were compared with the CCD spectra, and we found the difference between the two was 2.5%.

The measurements were taken using a commercial flatbed scanner instead of a microdensitometer.

The results indicate that the following two statements are inaccurate: (1) Correct measurement of spectroscopic plates requires a microdensitometer, and a commercial flatbed scanner is insufficient; (2) The spectrophotometric accuracy of spectroscopic plate is approximately 10% accurate.

These results will encourage the creation and publication of a digital archive of spectroscopic plates.

This paper presents the measurement of spectroscopic plates, the method of recovering intensity spectra from photographic density spectra, the results of comparison with CCD spectra, and discusses the causes of the high accuracy spectra obtained with a commercial flatbed scanner.

Yanagisawa, Kenshi,Furusho, Reiko,Nemoto, Shiomi,Kasuga, Toshihiro,Iwashita, Yumi,Watanabe, Jun-ichi, 2024, Spectrophotometric accuracy of spectra obtained from spectroscopic plates measured with a commercial flatbed scanner

Document

Openen

Delen

Bron

Artikelen aanbevolen door ES/IODE AI

A rare case of localized peliosis hepatis during adjuvant chemotherapy including oxaliplatin mimicking a liver metastasis of colon cancer
peliosis hepatis metastatic liver tumor oxaliplatin oxaliplatin associated cancer metastatic tumor liver hepatis peliosis