Document detail
ID

oai:pubmedcentral.nih.gov:6924...

Topic
Public Health
Author
Nigatu, Dabere Haile, Demewoz Gebremichael, Bereket M Tiruneh, Yordanos
Langue
en
Editor

BMJ Publishing Group

Category

BMJ Open

Year

2019

listing date

12/14/2023

Keywords
maternally health study accuracy maternal low baby size
Metrics

Abstract

OBJECTIVES: The study was designed to evaluate the accuracy of maternally perceived baby birth size assessments as a measure of birth weight and examine factors influencing the accuracy of maternal size assessments.

STUDY DESIGN: Cross-sectional study.

SETTING: The study is based on national data from the 2016 Ethiopian Demographic and Health Survey.

PARTICIPANTS: We included 1455 children who had both birth size and birth weight data.

MAIN OUTCOME MEASURES: Predictive accuracy of baby birth size for low birth weight.

Level of discordance between maternally perceived birth size and birth weight including factors influencing discordance.

RESULTS: Mother-reported baby birth size had low sensitivity (57%) and positive predictive value (41%) to indicate low birth weight but had high specificity (89%) and negative predictive values (94%).

The per cent of agreement between birth weight (<2500 g vs ≥2500 g) and maternally perceived birth size (small size vs average or above) was 86% and kappa statistics indicated a moderate level of agreement (kappa=0.41, p<0.001).

Maternal age, wealth index quintile, marital status and maternal education were significant predictors of the discordance between birth size and birth weight.

CONCLUSIONS: Maternal assessment of baby size at birth is an inaccurate proxy indicator of low birth weight in Ethiopia.

Therefore, a mother’s recall of birth size should be used as a proxy indicator for low birth weight with caution and should take maternal characteristics into consideration.

Nigatu, Dabere,Haile, Demewoz,Gebremichael, Bereket,M Tiruneh, Yordanos, 2019, Predictive accuracy of perceived baby birth size for birth weight: a cross-sectional study from the 2016 Ethiopian Demographic and Health Survey, BMJ Publishing Group

Document

Open Open

Share

Source

Articles recommended by ES/IODE AI

A Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière Disease
ménière disease p < detection imaging sequences 3d-zoomit 3d endolymphatic real tse reconstruction ir inversion-recovery hydrops ratio
Successful omental flap coverage repair of a rectovaginal fistula after low anterior resection: a case report
rectovaginal fistula rectal cancer low anterior resection omental flap muscle flap rectal cancer pod initial repair rvf flap omental lar coverage