Dokumentdetails
ID

doi:10.1186/s12893-024-02360-z...

Autor
Guo, Hanjie Zhang, Yuxing Ren, Saiyu Yang, Xiaodong Tian, Lei Huang, Yun Zhang, Chaojun Zhang, Xiliang
Langue
en
Editor

BioMed Central

Kategorie

Medicine & Public Health

Jahr

2024

Auflistungsdatum

17.04.2024

Schlüsselwörter
parathyroid glands methylene blue superior thyroid artery intraoperative parathyroid protect... retrograde registration patients method thyroid parathyroid
Metrisch

Zusammenfassung

Background Postoperative hypoparathyroidism caused by parathyroid injury is a problem faced by thyroid surgeons.

The current technologies for parathyroid imaging all have some defects.

Methods Patients with differentiated thyroid carcinoma (DTC) who underwent unilateral thyroidectomy plus ipsilateral central lymph node dissection were recruited.

We dissected the main trunk of the superior thyroid artery entering the thyroid gland and placed the venous indwelling tube into the artery.

The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated.

Results A total of 132 patients enrolled in this single-arm clinical trial, 105 of them completed retrograde catheterization via the superior artery.

The sensitivity was 69.23 and 83.33% respectively.

The specificity was 72.91 and 64.89%.

The accuracy was 72.91 and 64.89%.

The PPV was 85.71 and 81.08%.

The NPV was 22.58 and 45.45%.

There were no patients with allergic reactions to the methylene blue, or methylene blue toxicity.

Conclusions Retrograde injection of methylene blue via the superior thyroid artery is an effective and safe method to visualize parathyroid glands.

This method can accurately locate the target organ by ultraselecting the blood vessel and injecting the contrast agent while avoiding background contamination and reducing the amount of contrast agent.

Trial registration Clinical trial registration numbers and date of registration: ChiCTR2300077263、02/11/2023.

Guo, Hanjie,Zhang, Yuxing,Ren, Saiyu,Yang, Xiaodong,Tian, Lei,Huang, Yun,Zhang, Chaojun,Zhang, Xiliang, 2024, Real-time imaging of ipsilateral parathyroid glands by retrograde injection of methylene blue into the superior thyroid artery: a new intraoperative parathyroid protection method, BioMed Central

Dokumentieren

Öffnen

Teilen

Quelle

Artikel empfohlen von ES/IODE AI

Lung cancer risk and exposure to air pollution: a multicenter North China case–control study involving 14604 subjects
lung cancer case–control air pollution never-smokers nomogram model controls lung-related 14604 subjects north polluted consistent smokers quit exposure lung cancer risk air people factor smoking pollution study history